Answer before reviewing
Read the scenario for the setting, the patient and the one detail that decides it, then choose the single best answer. Read why each of the other three options falls short.
No sign-up needed
20 questions, each with a clear explanation.
Question review
Try the set above first, then use this list to review. Each answer and explanation stays closed until you open it.
Correct answer: C · A fit-tested N95 or higher-level respirator, put on before you go in
CDC's Transmission-Based Precautions page puts patients with suspected tuberculosis on Airborne Precautions in an airborne infection isolation room and calls for healthcare personnel to wear a fit-tested, NIOSH-approved N95 or higher-level respirator. A surgical mask is the mask CDC lists for Droplet Precautions, and a short exam doesn't change the airborne rule. Gloves protect the hands, not the airway. Moving the patient out to the department adds a trip that CDC asks to limit to medically necessary ones, which is why the portable unit comes to the room.
Look for this next time: For a patient on Airborne Precautions, put on a fit-tested N95 or higher-level respirator before entering, and bring the portable unit to the room.
Correct answer: A · Nothing to eat, drink or chew after midnight; ask us about morning pills
RadiologyInfo's upper GI page says the stomach must be empty of food for the best image quality, so patients are usually told not to eat, drink or chew gum after midnight the night before. It also says to confirm with the radiology department whether to take oral medications with sips of water, since some may be critical. A light breakfast leaves food in the stomach. Drinking clear liquids all morning breaks the nothing-by-mouth instruction. Stopping every medicine without asking skips the check the page calls for.
Look for this next time: Before an upper GI series the stomach must be empty, usually nothing by mouth after midnight, and the patient confirms with the department which morning medicines to take.
Correct answer: D · The plain abdominal radiograph first, then the barium upper GI series
RadiologyInfo's abdominal x-ray page asks patients to report a barium contrast exam in the last few days because it may interfere with the abdominal image, and its upper GI page notes that barium can color stools for 48 to 72 hours, so it stays in the bowel well beyond a few hours. Doing the plain abdominal radiograph first keeps barium out of it. Barium is the contrast that coats the GI tract so it can be imaged, so it does show. ARRT's 2027 outline lists scheduling and sequencing examinations as a Patient Care topic.
Look for this next time: Schedule a plain abdominal radiograph before a barium study, because barium left in the bowel can interfere with the image for days.
Correct answer: B · Sievert (Sv)
ARRT's 2027 Radiography content specifications make SI units the primary units on the exam and list them from NCRP Report No. 184: absorbed dose and air kerma in gray, exposure in coulomb per kilogram, and dose equivalent and effective dose in sievert. EPA's Radiation Terms and Units page explains that effective dose adjusts absorbed dose for the type of radiation and the sensitivity of the organs exposed. The gray measures absorbed energy per kilogram, the coulomb per kilogram measures exposure, and the becquerel measures radioactivity, one decay per second.
Look for this next time: Effective dose is in sieverts; absorbed dose and air kerma are in grays, exposure in coulombs per kilogram, and radioactivity in becquerels.
Correct answer: D · 50 mSv (5 rem)
Under 10 CFR 20.1201, an adult worker's annual total effective dose equivalent is limited to 5 rems (0.05 Sv), which is 50 mSv; EPA's Radiation Terms and Units page gives the same 0.05 Sv worker limit. The other figures are different NRC limits: 1 mSv (0.1 rem) a year is the limit for individual members of the public in 10 CFR 20.1301, 5 mSv (0.5 rem) is the limit for the embryo or fetus of a declared pregnant worker over the entire pregnancy in 10 CFR 20.1208, and 150 mSv (15 rem) is the annual lens dose equivalent limit for the eye.
Look for this next time: The NRC's annual occupational limit is 50 mSv (5 rem) total effective dose equivalent; the public limit is 1 mSv a year, and the embryo or fetus limit is 5 mSv for the whole pregnancy.
Correct answer: A · Risk rises in proportion to dose, and no dose is assumed to be risk-free
EPA's Radiation Health Effects page says the LNT model assumes the cancer risk from a low-dose exposure is proportional to dose with no threshold, so halving the dose halves the risk. ARRT's 2027 outline contrasts deterministic effects (tissue reactions) with stochastic ones, and a risk that rises with dose and has no threshold is the stochastic kind. A threshold describes effects like acute radiation syndrome, which EPA says takes a very high exposure, more than 0.75 gray, and causes nausea and vomiting within hours. A risk-free cutoff at 1 mSv contradicts the no-threshold assumption.
Look for this next time: The LNT model treats cancer risk as proportional to dose with no threshold, unlike acute effects that need a very high dose.
Correct answer: C · Leave the grid out, since the forearm is under 10 to 12 cm thick
Image Gently's digital radiography page and its 2012 special report in Radiologic Technology list actions for children: measure the body part with calipers, use a thickness-based technique chart for child-size technique, avoid grids for body parts less than 10 to 12 cm thick, and use automatic exposure control only when appropriate. A 6 cm forearm is well under that thickness, so the grid stays out. The report warns that AEC may not work well for small pediatric body parts, and an adult chart ignores the child-size technique the guidance asks for.
Look for this next time: For children, measure the part and leave the grid out when it is under 10 to 12 cm thick, using a child-size technique chart.
Correct answer: B · Collimate to the hand before exposing, then check the exposure indicator
Image Gently's actions for pediatric digital radiography include collimating prior to exposure and reviewing exposure indicators and image quality. ARRT's 2027 outline lists electronic cropping or masking as a postprocessing step and lists cropping or masking off anatomy under manipulation of electronic data, a legal topic. Masking changes only the displayed image after the x-rays have passed through the child, so it removes no dose. Nothing in this guidance requires exposing the whole detector, and lowering the mAs does not shrink the irradiated area.
Look for this next time: Collimate to the anatomy before the exposure; electronic masking afterward hides the extra area but does not remove the dose.
Correct answer: A · Raising the mAs while keeping the kVp unchanged
ARRT's factors table marks mAs as affecting receptor exposure only. It marks kVp as affecting receptor exposure, image contrast and subject contrast, so raising the kVp changes contrast. OID affects image contrast, spatial resolution and distortion, and focal spot size affects spatial resolution. Image Gently's 2012 special report on exposure indicators adds that the exposure index responds linearly to changes in mAs at a fixed kVp, which is why mAs is the factor to adjust when only receptor exposure needs to change.
Look for this next time: In ARRT's factors table, mAs changes receptor exposure only, while kVp also changes image and subject contrast.
Correct answer: D · About twice the target; keep it and lower the next technique
Image Gently's 2012 special report on exposure indicators explains that the DI equals 10 times the log of the exposure index over the target exposure index, so 0 is on target, +1 is about 26% more exposure and +3 is twice the target, while −3 is half. Repeating a diagnostic image because of its exposure index would add patient dose, and the report says not to. The DI is feedback for the next exposure: overexposed digital images look sharp, so the extra dose can go unnoticed unless the technique is corrected.
Look for this next time: A DI of +3 means about twice the target exposure; keep a diagnostic image and lower the technique next time.
Correct answer: C · Too little exposure at the detector, showing as quantum mottle
Image Gently's 2012 special report says underexposed digital images can be recognized by a noisy, grainy appearance called quantum mottle, while overexposed images are typically sharp with low noise. A DI of −3 means about half the target exposure, which fits. The stem rules out motion, and ARRT's factors table links motion to spatial resolution, which shows as blur rather than grain. The same table links grids to receptor exposure and image contrast, so a missing grid does not explain graininess across the field with a DI of −3.
Look for this next time: Graininess with a negative DI points to underexposure and quantum mottle; overexposed digital images look smooth.
Correct answer: B · The window width
Under postprocessing, ARRT's 2027 outline pairs brightness with window level and contrast with window width, so the window width is the control for contrast. Changing the window level would shift brightness, which the radiologist wants to keep. The outline lists region of interest and stitching as separate postprocessing items, and neither is the control it ties to contrast. Image Gently's 2012 report adds that digital processing adjusts brightness, contrast and grayscale, which is also why the displayed image says little about the exposure itself.
Look for this next time: Window width controls displayed contrast, and window level controls brightness.
Correct answer: A · It exceeds the 2 cm allowed at this SID; report it for service
21 CFR 1020.31(d)(2) says the total misalignment of the edges of the visually defined field with the x-ray field, along either the length or the width, must not exceed 2% of the distance from the source to the center of the visually defined field. At 100 cm that is 2 cm, so 3 cm fails. The limit is 2%, not 5%, and it applies to length and width alike. Opening the collimator wider would irradiate more of the patient than the light shows. ARRT's 2027 outline lists light field to radiation field alignment and reporting malfunctions under quality control.
Look for this next time: Light field and x-ray field edges must align within 2% of the SID along length and width; report a unit that fails.
Correct answer: D · Horizontal-beam cross-table lateral (Danelius-Miller)
ARRT's 2027 Attachment A labels the unilateral frog-leg as non-trauma and lists the cross-table (horizontal beam) lateral hip, named Danelius-Miller, and the axiolateral inferosuperior trauma projection, named Clements-Nakayama, for the hip. With the beam directed across the table, the lateral is taken without moving the injured leg. A bilateral frog-leg AP pelvis would also mean moving the injured leg into the frog-leg position. The Judet projection is a posterior oblique of the pelvis for the acetabulum, not a lateral of the hip.
Look for this next time: For a suspected hip fracture, use a trauma lateral such as the cross-table (Danelius-Miller); ARRT labels the frog-leg non-trauma.
Correct answer: B · By tilting the table under fluoroscopy so the contrast flows up
RadiologyInfo's myelography page says the contrast is usually injected into the lower lumbar spinal canal, with the needle tip in the subarachnoid space, and that the radiologist then slowly tilts the x-ray table under fluoroscopy so the contrast flows up or down around the nerve roots or spinal cord, focusing on the area that matches the symptoms. The page describes an upper cervical injection only as an occasional alternative site, not as a second dose. Walking is not part of the procedure, and the two hours it mentions are the observation period afterward.
Look for this next time: In myelography, contrast usually enters the lower lumbar subarachnoid space and is moved to the level of interest by tilting the table.
Correct answer: C · Use a water-soluble contrast solution instead of barium
RadiologyInfo's lower GI page says that if perforation of the colon is suspected, the enema should be performed with a water-soluble contrast solution, and it warns that barium could leak through an undetected hole and inflame the surrounding tissue. Adding air or extending the bowel preparation still uses barium. The abdominal x-ray page says a standing image can help show perforations, but it does not say a plain image replaces an ordered contrast enema. ARRT's 2027 outline lists perforated bowel as a patient condition that affects which contrast is appropriate.
Look for this next time: When colon perforation is suspected, a contrast enema uses water-soluble contrast rather than barium.
Correct answer: A · 7 to 10 days after her period starts, before ovulation
RadiologyInfo's HSG page says to schedule the exam seven to 10 days after the first day of the menstrual period, but before ovulation, and not to have it with an active pelvic infection; it also asks patients to tell the doctor and technologist if they are pregnant. The first days of the period fall before that window, and a slot just after ovulation falls after it. Fasting from midnight is upper GI preparation; the HSG page gives a timing rule instead.
Look for this next time: Book an HSG seven to 10 days after the first day of the period and before ovulation.
Correct answer: B · To compare the injury with the child's normal growth plates
RadiologyInfo's bone x-ray page says an x-ray may also be taken of the unaffected limb, or of a child's growth plate, for comparison, and that two or three images from different angles are typically taken. A comparison view does not replace a projection of the injured side. Image Gently's 2012 report explains that target exposure index values are set for each body part and projection by the manufacturer or the facility, not from a second patient image. Nothing in the request points to a hidden second injury.
Look for this next time: In children, an image of the uninjured side can be taken to compare against the normal growth plates.
Correct answer: D · Eight
NCI's SEER Training page on the appendicular skeleton counts 16 carpals for both upper limbs, which is eight in each wrist. The other numbers belong to other groups on the same page: 10 metacarpals make five per hand, 14 tarsals make seven per foot, and 28 phalanges in the upper limbs make 14 per hand. Knowing the count helps you confirm that wrist projections listed in ARRT's 2027 outline, such as the PA and the PA with ulnar deviation, include every carpal bone.
Look for this next time: Each wrist has eight carpal bones; each hand has five metacarpals and 14 phalanges.
Correct answer: C · AP partial flexion, with the elbow left bent
ARRT's 2027 Attachment A lists these elbow projections: AP, lateral, lateral oblique, medial oblique, AP partial flexion and the trauma axial laterals (Coyle). The patient cannot straighten the elbow, so the AP and both obliques taken with the elbow extended are ruled out by the stem. The AP partial flexion is the listed projection named for a partly bent elbow, which makes it the adaptation for this patient. ARRT's 2027 outline lists procedure adaptation for trauma and limited mobility as a Procedures topic.
Look for this next time: When an elbow can't be extended, adapt with the AP partial flexion rather than forcing the joint straight.
Use the sample well
A short set can show you what deserves another look. Twenty questions are a small sample, so this set cannot measure readiness for the 230-question ARRT Radiography exam or predict a scaled 75 on ARRT's 1–99 scale.
Read the scenario for the setting, the patient and the one detail that decides it, then choose the single best answer. Read why each of the other three options falls short.
Confirm why the best option fits, even when you were right.
Use recurring misses—not one score—to choose your next focus.
Full ARRT (R) prep
Want more than 20 questions?
At launch: 550 exam-style ARRT (R) questions and 600 flashcards, practiced one content category at a time.
Explore Full ARRT (R) PrepFree ARRT (R) resources
Open the exam overview, build a study plan, or browse the ARRT (R) guides.
Review the exam format, official sources, and preparation options.
Open exam hub →Practical planning aidTurn the time you have into a clear study rhythm.
Build my outline →Source-backed answersGo straight to the question already on your mind.
Browse guides →