No sign-up needed

Free ARRT Radiography practice test

20 questions, each with a clear explanation.

Quick PracticeQuestion 1 of 20
Your progress through this set
Patient CareStep 1 · Choose one answer

You are sent with a portable unit to take a chest radiograph of a patient with suspected pulmonary tuberculosis who is in an airborne infection isolation room. Under CDC's Transmission-Based Precautions, what do you need before you enter the room?

Question review

All 20 ARRT (R) questions with explanations

Try the set above first, then use this list to review. Each answer and explanation stays closed until you open it.

  1. Question 1 · Patient Care

    You are sent with a portable unit to take a chest radiograph of a patient with suspected pulmonary tuberculosis who is in an airborne infection isolation room. Under CDC's Transmission-Based Precautions, what do you need before you enter the room?

    1. A surgical mask, since the exam itself lasts only a few minutes
    2. Clean gloves, since you won't touch the patient for very long
    3. A fit-tested N95 or higher-level respirator, put on before you go in
    4. Nothing extra, if the patient is moved down to the x-ray room instead
    Show answer and explanation for question 1

    Correct answer: C · A fit-tested N95 or higher-level respirator, put on before you go in

    CDC's Transmission-Based Precautions page puts patients with suspected tuberculosis on Airborne Precautions in an airborne infection isolation room and calls for healthcare personnel to wear a fit-tested, NIOSH-approved N95 or higher-level respirator. A surgical mask is the mask CDC lists for Droplet Precautions, and a short exam doesn't change the airborne rule. Gloves protect the hands, not the airway. Moving the patient out to the department adds a trip that CDC asks to limit to medically necessary ones, which is why the portable unit comes to the room.

    Look for this next time: For a patient on Airborne Precautions, put on a fit-tested N95 or higher-level respirator before entering, and bring the portable unit to the room.

  2. Question 2 · Patient Care

    A patient booked for a morning upper GI series calls the day before to ask how to prepare. Which answer matches the preparation that RadiologyInfo, the patient site of the ACR and RSNA, describes for this exam?

    1. Nothing to eat, drink or chew after midnight; ask us about morning pills
    2. A light breakfast is fine, since the barium will coat the stomach anyway
    3. Clear liquids are fine all morning, as long as you skip solid food
    4. Stop all of your usual medicines that morning, without asking anyone
    Show answer and explanation for question 2

    Correct answer: A · Nothing to eat, drink or chew after midnight; ask us about morning pills

    RadiologyInfo's upper GI page says the stomach must be empty of food for the best image quality, so patients are usually told not to eat, drink or chew gum after midnight the night before. It also says to confirm with the radiology department whether to take oral medications with sips of water, since some may be critical. A light breakfast leaves food in the stomach. Drinking clear liquids all morning breaks the nothing-by-mouth instruction. Stopping every medicine without asking skips the check the page calls for.

    Look for this next time: Before an upper GI series the stomach must be empty, usually nothing by mouth after midnight, and the patient confirms with the department which morning medicines to take.

  3. Question 3 · Patient Care

    An outpatient has orders for an abdominal radiograph and a barium upper GI series on the same morning. In which order should the two exams be done?

    1. The upper GI first, then the abdominal image while the barium is fresh
    2. Either order works, as barium doesn't show on plain images
    3. The upper GI first, with the abdominal image a few hours afterward
    4. The plain abdominal radiograph first, then the barium upper GI series
    Show answer and explanation for question 3

    Correct answer: D · The plain abdominal radiograph first, then the barium upper GI series

    RadiologyInfo's abdominal x-ray page asks patients to report a barium contrast exam in the last few days because it may interfere with the abdominal image, and its upper GI page notes that barium can color stools for 48 to 72 hours, so it stays in the bowel well beyond a few hours. Doing the plain abdominal radiograph first keeps barium out of it. Barium is the contrast that coats the GI tract so it can be imaged, so it does show. ARRT's 2027 outline lists scheduling and sequencing examinations as a Patient Care topic.

    Look for this next time: Schedule a plain abdominal radiograph before a barium study, because barium left in the bowel can interfere with the image for days.

  4. Question 4 · Safety

    A patient's dose summary reports the effective dose from her exam. In which SI unit is effective dose expressed?

    1. Gray (Gy)
    2. Sievert (Sv)
    3. Coulomb per kilogram (C/kg)
    4. Becquerel (Bq)
    Show answer and explanation for question 4

    Correct answer: B · Sievert (Sv)

    ARRT's 2027 Radiography content specifications make SI units the primary units on the exam and list them from NCRP Report No. 184: absorbed dose and air kerma in gray, exposure in coulomb per kilogram, and dose equivalent and effective dose in sievert. EPA's Radiation Terms and Units page explains that effective dose adjusts absorbed dose for the type of radiation and the sensitivity of the organs exposed. The gray measures absorbed energy per kilogram, the coulomb per kilogram measures exposure, and the becquerel measures radioactivity, one decay per second.

    Look for this next time: Effective dose is in sieverts; absorbed dose and air kerma are in grays, exposure in coulombs per kilogram, and radioactivity in becquerels.

  5. Question 5 · Safety

    A new radiographer reading her first dosimetry report asks what the annual occupational limit is. Under the U.S. Nuclear Regulatory Commission's limits for adult workers in 10 CFR 20.1201, what is the annual limit on total effective dose equivalent?

    1. 1 mSv (0.1 rem)
    2. 5 mSv (0.5 rem)
    3. 150 mSv (15 rem)
    4. 50 mSv (5 rem)
    Show answer and explanation for question 5

    Correct answer: D · 50 mSv (5 rem)

    Under 10 CFR 20.1201, an adult worker's annual total effective dose equivalent is limited to 5 rems (0.05 Sv), which is 50 mSv; EPA's Radiation Terms and Units page gives the same 0.05 Sv worker limit. The other figures are different NRC limits: 1 mSv (0.1 rem) a year is the limit for individual members of the public in 10 CFR 20.1301, 5 mSv (0.5 rem) is the limit for the embryo or fetus of a declared pregnant worker over the entire pregnancy in 10 CFR 20.1208, and 150 mSv (15 rem) is the annual lens dose equivalent limit for the eye.

    Look for this next time: The NRC's annual occupational limit is 50 mSv (5 rem) total effective dose equivalent; the public limit is 1 mSv a year, and the embryo or fetus limit is 5 mSv for the whole pregnancy.

  6. Question 6 · Safety

    EPA bases its limits for low-level radiation on the linear no-threshold (LNT) model. How does that model treat the cancer risk from a low dose?

    1. Risk rises in proportion to dose, and no dose is assumed to be risk-free
    2. Risk starts only above a threshold, like the one for radiation sickness
    3. Risk shows up within hours as nausea and vomiting after the exposure
    4. Risk is zero below 1 mSv and rises steeply only above that dose level
    Show answer and explanation for question 6

    Correct answer: A · Risk rises in proportion to dose, and no dose is assumed to be risk-free

    EPA's Radiation Health Effects page says the LNT model assumes the cancer risk from a low-dose exposure is proportional to dose with no threshold, so halving the dose halves the risk. ARRT's 2027 outline contrasts deterministic effects (tissue reactions) with stochastic ones, and a risk that rises with dose and has no threshold is the stochastic kind. A threshold describes effects like acute radiation syndrome, which EPA says takes a very high exposure, more than 0.75 gray, and causes nausea and vomiting within hours. A risk-free cutoff at 1 mSv contradicts the no-threshold assumption.

    Look for this next time: The LNT model treats cancer risk as proportional to dose with no threshold, unlike acute effects that need a very high dose.

  7. Question 7 · Safety

    A 5-year-old needs forearm radiographs in a digital room, and calipers measure the forearm at 6 cm. Following Image Gently's guidance for pediatric digital radiography, how should you handle the grid?

    1. Use the grid, since it improves contrast on every pediatric image
    2. Use the grid and let AEC set the exposure for the small forearm
    3. Leave the grid out, since the forearm is under 10 to 12 cm thick
    4. Use the grid with the adult chart, then fix the image afterward
    Show answer and explanation for question 7

    Correct answer: C · Leave the grid out, since the forearm is under 10 to 12 cm thick

    Image Gently's digital radiography page and its 2012 special report in Radiologic Technology list actions for children: measure the body part with calipers, use a thickness-based technique chart for child-size technique, avoid grids for body parts less than 10 to 12 cm thick, and use automatic exposure control only when appropriate. A 6 cm forearm is well under that thickness, so the grid stays out. The report warns that AEC may not work well for small pediatric body parts, and an adult chart ignores the child-size technique the guidance asks for.

    Look for this next time: For children, measure the part and leave the grid out when it is under 10 to 12 cm thick, using a child-size technique chart.

  8. Question 8 · Safety

    For a child's hand radiograph, a coworker opens the collimator to the full detector and plans to mask the extra area electronically after the exposure. What should you suggest?

    1. Mask afterward, since masking removes the dose outside the hand
    2. Collimate to the hand before exposing, then check the exposure indicator
    3. Keep the full field, since a digital detector must be fully exposed
    4. Keep the full field and mask, but lower the mAs to offset the area
    Show answer and explanation for question 8

    Correct answer: B · Collimate to the hand before exposing, then check the exposure indicator

    Image Gently's actions for pediatric digital radiography include collimating prior to exposure and reviewing exposure indicators and image quality. ARRT's 2027 outline lists electronic cropping or masking as a postprocessing step and lists cropping or masking off anatomy under manipulation of electronic data, a legal topic. Masking changes only the displayed image after the x-rays have passed through the child, so it removes no dose. Nothing in this guidance requires exposing the whole detector, and lowering the mAs does not shrink the irradiated area.

    Look for this next time: Collimate to the anatomy before the exposure; electronic masking afterward hides the extra area but does not remove the dose.

  9. Question 9 · Image Production

    A radiographer wants more receptor exposure on a knee image without changing image contrast or subject contrast. In the factors table of ARRT's 2027 Radiography content specifications, which change affects receptor exposure alone?

    1. Raising the mAs while keeping the kVp unchanged
    2. Raising the kVp while the mAs stays the same
    3. Increasing the OID at the same SID
    4. Switching from the large to the small focal spot
    Show answer and explanation for question 9

    Correct answer: A · Raising the mAs while keeping the kVp unchanged

    ARRT's factors table marks mAs as affecting receptor exposure only. It marks kVp as affecting receptor exposure, image contrast and subject contrast, so raising the kVp changes contrast. OID affects image contrast, spatial resolution and distortion, and focal spot size affects spatial resolution. Image Gently's 2012 special report on exposure indicators adds that the exposure index responds linearly to changes in mAs at a fixed kVp, which is why mAs is the factor to adjust when only receptor exposure needs to change.

    Look for this next time: In ARRT's factors table, mAs changes receptor exposure only, while kVp also changes image and subject contrast.

  10. Question 10 · Image Production

    A digital lateral lumbar spine image is sharp and diagnostic, and the workstation shows a deviation index (DI) of +3 for the correct body part and projection. What does this mean, and what should you do?

    1. About 30% over target; repeat the image with a lower mAs
    2. About half the target; repeat the image with a higher mAs setting
    3. Right on target; keep the same technique next time
    4. About twice the target; keep it and lower the next technique
    Show answer and explanation for question 10

    Correct answer: D · About twice the target; keep it and lower the next technique

    Image Gently's 2012 special report on exposure indicators explains that the DI equals 10 times the log of the exposure index over the target exposure index, so 0 is on target, +1 is about 26% more exposure and +3 is twice the target, while −3 is half. Repeating a diagnostic image because of its exposure index would add patient dose, and the report says not to. The DI is feedback for the next exposure: overexposed digital images look sharp, so the extra dose can go unnoticed unless the technique is corrected.

    Look for this next time: A DI of +3 means about twice the target exposure; keep a diagnostic image and lower the technique next time.

  11. Question 11 · Image Production

    A digital AP knee image looks grainy across the whole field, and the deviation index (DI) is −3. Positioning was correct and the patient held still. What is the most likely cause?

    1. Scatter, because the image was taken without a grid
    2. Overexposure that saturated the detector in the thinner soft tissue
    3. Too little exposure at the detector, showing as quantum mottle
    4. Patient motion during the exposure, which blurred the bony edges
    Show answer and explanation for question 11

    Correct answer: C · Too little exposure at the detector, showing as quantum mottle

    Image Gently's 2012 special report says underexposed digital images can be recognized by a noisy, grainy appearance called quantum mottle, while overexposed images are typically sharp with low noise. A DI of −3 means about half the target exposure, which fits. The stem rules out motion, and ARRT's factors table links motion to spatial resolution, which shows as blur rather than grain. The same table links grids to receptor exposure and image contrast, so a missing grid does not explain graininess across the field with a DI of −3.

    Look for this next time: Graininess with a negative DI points to underexposure and quantum mottle; overexposed digital images look smooth.

  12. Question 12 · Image Production

    At the PACS workstation, a radiologist asks you to show more contrast between soft tissue and bone without changing the overall brightness. Which postprocessing control does ARRT's 2027 Radiography outline pair with contrast?

    1. The window level
    2. The window width
    3. A new region of interest
    4. Image stitching
    Show answer and explanation for question 12

    Correct answer: B · The window width

    Under postprocessing, ARRT's 2027 outline pairs brightness with window level and contrast with window width, so the window width is the control for contrast. Changing the window level would shift brightness, which the radiologist wants to keep. The outline lists region of interest and stitching as separate postprocessing items, and neither is the control it ties to contrast. Image Gently's 2012 report adds that digital processing adjusts brightness, contrast and grayscale, which is also why the displayed image says little about the exposure itself.

    Look for this next time: Window width controls displayed contrast, and window level controls brightness.

  13. Question 13 · Image Production

    During a quality control check at a 100 cm SID, the edges of the light field and the x-ray field are misaligned by a total of 3 cm along the length of the field. Under the federal performance standard in 21 CFR 1020.31, what does this result mean?

    1. It exceeds the 2 cm allowed at this SID; report it for service
    2. It passes, because the standard allows up to 5% of the SID
    3. It passes, because only the width of the field is measured
    4. It passes if you open the collimator 3 cm wider for each exam
    Show answer and explanation for question 13

    Correct answer: A · It exceeds the 2 cm allowed at this SID; report it for service

    21 CFR 1020.31(d)(2) says the total misalignment of the edges of the visually defined field with the x-ray field, along either the length or the width, must not exceed 2% of the distance from the source to the center of the visually defined field. At 100 cm that is 2 cm, so 3 cm fails. The limit is 2%, not 5%, and it applies to length and width alike. Opening the collimator wider would irradiate more of the patient than the light shows. ARRT's 2027 outline lists light field to radiation field alignment and reporting malfunctions under quality control.

    Look for this next time: Light field and x-ray field edges must align within 2% of the SID along length and width; report a unit that fails.

  14. Question 14 · Procedures

    An emergency patient with a suspected hip fracture has a shortened, externally rotated leg, and the order says not to move it. Which lateral hip projection from ARRT's 2027 Radiography list (Attachment A) fits?

    1. Unilateral frog-leg lateral of the injured hip
    2. AP pelvis with both hips in the frog-leg position
    3. Posterior oblique of the pelvis for the acetabulum (Judet)
    4. Horizontal-beam cross-table lateral (Danelius-Miller)
    Show answer and explanation for question 14

    Correct answer: D · Horizontal-beam cross-table lateral (Danelius-Miller)

    ARRT's 2027 Attachment A labels the unilateral frog-leg as non-trauma and lists the cross-table (horizontal beam) lateral hip, named Danelius-Miller, and the axiolateral inferosuperior trauma projection, named Clements-Nakayama, for the hip. With the beam directed across the table, the lateral is taken without moving the injured leg. A bilateral frog-leg AP pelvis would also mean moving the injured leg into the frog-leg position. The Judet projection is a posterior oblique of the pelvis for the acetabulum, not a lateral of the hip.

    Look for this next time: For a suspected hip fracture, use a trauma lateral such as the cross-table (Danelius-Miller); ARRT labels the frog-leg non-trauma.

  15. Question 15 · Procedures

    During a lumbar myelogram, contrast has been injected and the patient's symptoms point to a level higher in the spine. According to RadiologyInfo's myelography page, how does the radiologist usually move the contrast to that level?

    1. By injecting a second dose of contrast at that level
    2. By tilting the table under fluoroscopy so the contrast flows up
    3. By having the patient walk for a few minutes before imaging
    4. By waiting about two hours for the contrast to spread out evenly
    Show answer and explanation for question 15

    Correct answer: B · By tilting the table under fluoroscopy so the contrast flows up

    RadiologyInfo's myelography page says the contrast is usually injected into the lower lumbar spinal canal, with the needle tip in the subarachnoid space, and that the radiologist then slowly tilts the x-ray table under fluoroscopy so the contrast flows up or down around the nerve roots or spinal cord, focusing on the area that matches the symptoms. The page describes an upper cervical injection only as an occasional alternative site, not as a second dose. Walking is not part of the procedure, and the two hours it mentions are the observation period afterward.

    Look for this next time: In myelography, contrast usually enters the lower lumbar subarachnoid space and is moved to the level of interest by tilting the table.

  16. Question 16 · Procedures

    A contrast enema is ordered for a patient whose physician suspects a perforation of the colon. What does RadiologyInfo's lower GI page say about the contrast for this exam?

    1. Use barium with air, for a double-contrast study
    2. Use barium after a longer bowel preparation
    3. Use a water-soluble contrast solution instead of barium
    4. Skip contrast; a standing abdominal image replaces the enema
    Show answer and explanation for question 16

    Correct answer: C · Use a water-soluble contrast solution instead of barium

    RadiologyInfo's lower GI page says that if perforation of the colon is suspected, the enema should be performed with a water-soluble contrast solution, and it warns that barium could leak through an undetected hole and inflame the surrounding tissue. Adding air or extending the bowel preparation still uses barium. The abdominal x-ray page says a standing image can help show perforations, but it does not say a plain image replaces an ordered contrast enema. ARRT's 2027 outline lists perforated bowel as a patient condition that affects which contrast is appropriate.

    Look for this next time: When colon perforation is suspected, a contrast enema uses water-soluble contrast rather than barium.

  17. Question 17 · Procedures

    A patient calls to book a hysterosalpingogram (HSG). According to RadiologyInfo's HSG page, when in her menstrual cycle should the exam be scheduled?

    1. 7 to 10 days after her period starts, before ovulation
    2. During the first two days of her period, while bleeding
    3. Just after ovulation, around the middle of her cycle
    4. Any day of her cycle, if she fasts from midnight on
    Show answer and explanation for question 17

    Correct answer: A · 7 to 10 days after her period starts, before ovulation

    RadiologyInfo's HSG page says to schedule the exam seven to 10 days after the first day of the menstrual period, but before ovulation, and not to have it with an active pelvic infection; it also asks patients to tell the doctor and technologist if they are pregnant. The first days of the period fall before that window, and a slot just after ovulation falls after it. Fasting from midnight is upper GI preparation; the HSG page gives a timing rule instead.

    Look for this next time: Book an HSG seven to 10 days after the first day of the period and before ovulation.

  18. Question 18 · Procedures

    After imaging a 7-year-old's injured elbow, the radiologist asks for an image of the uninjured elbow too. According to RadiologyInfo's bone x-ray page, why can this be requested?

    1. To give the exposure indicator a new target for the next image
    2. To compare the injury with the child's normal growth plates
    3. To replace the lateral projection, which children can't hold
    4. To find a second injury that the child did not mention
    Show answer and explanation for question 18

    Correct answer: B · To compare the injury with the child's normal growth plates

    RadiologyInfo's bone x-ray page says an x-ray may also be taken of the unaffected limb, or of a child's growth plate, for comparison, and that two or three images from different angles are typically taken. A comparison view does not replace a projection of the injured side. Image Gently's 2012 report explains that target exposure index values are set for each body part and projection by the manufacturer or the facility, not from a second patient image. Nothing in the request points to a hidden second injury.

    Look for this next time: In children, an image of the uninjured side can be taken to compare against the normal growth plates.

  19. Question 19 · Procedures

    A PA wrist radiograph of an adult is checked to make sure every carpal bone is in the field. How many carpal bones are in one wrist?

    1. Five
    2. Seven
    3. Fourteen
    4. Eight
    Show answer and explanation for question 19

    Correct answer: D · Eight

    NCI's SEER Training page on the appendicular skeleton counts 16 carpals for both upper limbs, which is eight in each wrist. The other numbers belong to other groups on the same page: 10 metacarpals make five per hand, 14 tarsals make seven per foot, and 28 phalanges in the upper limbs make 14 per hand. Knowing the count helps you confirm that wrist projections listed in ARRT's 2027 outline, such as the PA and the PA with ulnar deviation, include every carpal bone.

    Look for this next time: Each wrist has eight carpal bones; each hand has five metacarpals and 14 phalanges.

  20. Question 20 · Procedures

    After a fall, a patient holds his elbow bent at about 90 degrees and cannot straighten it. Which elbow projection from ARRT's 2027 Radiography list (Attachment A) is taken with the elbow partly flexed?

    1. AP with the elbow fully extended
    2. Medial oblique with the elbow fully extended
    3. AP partial flexion, with the elbow left bent
    4. Lateral oblique with the elbow fully extended
    Show answer and explanation for question 20

    Correct answer: C · AP partial flexion, with the elbow left bent

    ARRT's 2027 Attachment A lists these elbow projections: AP, lateral, lateral oblique, medial oblique, AP partial flexion and the trauma axial laterals (Coyle). The patient cannot straighten the elbow, so the AP and both obliques taken with the elbow extended are ruled out by the stem. The AP partial flexion is the listed projection named for a partly bent elbow, which makes it the adaptation for this patient. ARRT's 2027 outline lists procedure adaptation for trauma and limited mobility as a Procedures topic.

    Look for this next time: When an elbow can't be extended, adapt with the AP partial flexion rather than forcing the joint straight.

Use the sample well

The rationale matters more than the score.

A short set can show you what deserves another look. Twenty questions are a small sample, so this set cannot measure readiness for the 230-question ARRT Radiography exam or predict a scaled 75 on ARRT's 1–99 scale.

01

Answer before reviewing

Read the scenario for the setting, the patient and the one detail that decides it, then choose the single best answer. Read why each of the other three options falls short.

02

Read every rationale

Confirm why the best option fits, even when you were right.

03

Follow the pattern

Use recurring misses—not one score—to choose your next focus.