No sign-up needed

Free Journeyman Plumber practice test

20 questions, each with a clear explanation.

Quick PracticeQuestion 1 of 20
Your progress through this set
Administration General RegulationsStep 1 · Choose one answer

A plumber is repairing a leaking soldered joint on the copper line that feeds a kitchen faucet in a home. Under the federal lead-free rule for drinking-water plumbing, which solder may be used?

Question review

All 20 Journeyman Plumber questions with explanations

Try the set above first, then use this list to review. Each answer and explanation stays closed until you open it.

  1. Question 1 · Administration General Regulations

    A plumber is repairing a leaking soldered joint on the copper line that feeds a kitchen faucet in a home. Under the federal lead-free rule for drinking-water plumbing, which solder may be used?

    1. Solder that contains no more than 0.2 percent lead
    2. 50/50 tin-lead solder, as long as the line is flushed before use
    3. Any solder at all, since solder isn't regulated
    4. Solder with up to 2 percent lead, the allowance for repairs
    Show answer and explanation for question 1

    Correct answer: A · Solder that contains no more than 0.2 percent lead

    EPA's lead-free rule (40 CFR 143.12 and 143.13) defines lead-free solder and flux as containing no more than 0.2 percent lead, and it bars any solder or flux that isn't lead free from the installation or repair of plumbing that provides water for human consumption. Flushing the line doesn't make 50/50 tin-lead solder acceptable, and the rule names solder and flux alongside pipe, fittings and fixtures. It has no extra allowance for repairs: the only exception it lists is for leaded joints needed to repair cast iron pipe.

    Look for this next time: Solder and flux used on drinking-water plumbing may contain no more than 0.2 percent lead, and repairs follow the same rule.

  2. Question 2 · Administration General Regulations

    A supplier describes a new brass kitchen faucet as lead free under the federal Safe Drinking Water Act rule. What does that description mean?

    1. No part of the faucet, inside or out, contains any lead
    2. Each brass part of the faucet contains less than 8 percent lead by weight
    3. Its wetted surfaces average 0.25 percent lead or less, weighted by area
    4. It passed one tap-water test that showed no lead in the water
    Show answer and explanation for question 2

    Correct answer: C · Its wetted surfaces average 0.25 percent lead or less, weighted by area

    EPA's rule (40 CFR 143.12) defines lead free for pipes, fittings and fixtures as not more than a weighted average of 0.25 percent lead across the wetted surfaces, the surfaces water touches. Each wetted part's lead percentage is weighted by its share of the total wetted area, so lead free doesn't mean zero lead in every part. An 8 percent figure appears in the rule only as a per-part cap for drinking water coolers, and the definition rests on lead content, not on a single water test. Solder and flux have their own 0.2 percent limit.

    Look for this next time: Lead free on a pipe, fitting or fixture means its wetted surfaces average no more than 0.25 percent lead, weighted by area.

  3. Question 3 · Administration General Regulations

    An inspector is checking the air gap at a commercial sink filled by a faucet spout that ends above the bowl. Between which two points is the air gap measured?

    1. From the faucet's outlet to the bottom of the sink bowl below it
    2. From the faucet handle to the top edge of the sink's backsplash
    3. From the lowest opening of the faucet outlet to the flood-level rim
    4. From the faucet's outlet down to the overflow opening in the sink wall
    Show answer and explanation for question 3

    Correct answer: C · From the lowest opening of the faucet outlet to the flood-level rim

    EPA's Cross-Connection Control Manual defines an air gap as the unobstructed vertical distance through the free atmosphere between the lowest opening of the pipe or faucet supplying a fixture and the flood-level rim of the receptacle. The flood-level rim is the edge water would spill over, so measuring to the bottom of the bowl overstates the gap, and an overflow opening sits below the rim. The handle and the backsplash play no part in the definition. EPA adds that an air gap generally must be twice the diameter of the supply pipe and never less than 1 inch.

    Look for this next time: An air gap runs vertically from the lowest opening of the supply outlet to the flood-level rim of the fixture it fills.

  4. Question 4 · Administration General Regulations

    A water main break drops the pressure in the street main below atmospheric pressure. A garden hose left in a bucket of liquid fertilizer starts drawing the mixture back into the house piping. What is this type of backflow called?

    1. Backpressure, because the bucket pushes the fertilizer into the line
    2. Backsiphonage, because the supply piping is under negative pressure
    3. Thermal expansion in the house piping
    4. Water hammer, because the break sends a pressure surge up the line
    Show answer and explanation for question 4

    Correct answer: B · Backsiphonage, because the supply piping is under negative pressure

    EPA's Cross-Connection Control Manual defines backsiphonage as backflow resulting from negative pressures in the distributing pipes of a potable water supply. A main break that pulls the supply below atmospheric pressure creates that condition, and the hose submerged in the bucket is the cross-connection it acts through. Backpressure is the other type: flow toward the supply because a connected system, such as a boiler or a pumped line, is at a higher pressure than the potable water, and an open bucket isn't. Thermal expansion and water hammer describe pressure effects in the piping, not water drawn back from a container.

    Look for this next time: Backsiphonage is backflow driven by negative pressure in the supply; backpressure is backflow driven by higher pressure downstream.

  5. Question 5 · Administration General Regulations

    A plumbing floor plan is drawn at a scale of 1/4 inch = 1 foot. On the sheet, a building drain run measures 5 3/8 inches. How long is the run in the building?

    1. 43 feet
    2. 10 3/4 feet
    3. About 1.3 feet
    4. 21 1/2 feet
    Show answer and explanation for question 5

    Correct answer: D · 21 1/2 feet

    At 1/4 inch = 1 foot, each inch on the drawing stands for 4 feet, so 5 3/8 inches × 4 = 21 1/2 feet. Forty-three feet is what you'd get on a 1/8-inch scale, where each inch stands for 8 feet, and 10 3/4 feet fits a 1/2-inch scale. Dividing by 4 instead of multiplying gives about 1.3 feet. Plumbing sets often mix scales between plans and details, so read the scale printed on each sheet before you measure.

    Look for this next time: On a drawing at 1/4 inch = 1 foot, multiply the measured inches by 4 to get feet.

  6. Question 6 · Administration General Regulations

    During a water test of new drain and vent piping, the stack is filled until the water stands 10 feet above the lowest joint being tested. About how much pressure does the water put on that joint?

    1. About 23 psi
    2. 0.43 psi
    3. About 4.3 psi
    4. About 14.7 psi
    Show answer and explanation for question 6

    Correct answer: C · About 4.3 psi

    EPA's Cross-Connection Control Manual explains that a foot-high column of water puts about 0.433 psi on its base, because a cubic foot of water weighs about 62.4 pounds spread over 144 square inches. Ten feet of water therefore puts about 4.3 psi on the lowest joint. About 23 psi comes from multiplying by 2.31, the feet-per-psi factor, in the wrong direction. 0.43 psi is the pressure of a single foot, and 14.7 psi is sea-level atmospheric pressure, which a gauge reads as zero.

    Look for this next time: Each foot of water adds about 0.433 psi, so a 10-foot head puts about 4.3 psi on the lowest point.

  7. Question 7 · Administration General Regulations

    A crew digs a trench 6 feet deep in ordinary soil to install a building sewer. Under OSHA's excavation rules, what must protect workers who enter the trench?

    1. A spotter who watches the trench walls while they work
    2. A protective system such as sloping, shoring or a trench shield
    3. Hard hats and high-visibility vests, since the soil looks dry and firm
    4. A ladder at each end of the trench, in place of shoring
    Show answer and explanation for question 7

    Correct answer: B · A protective system such as sloping, shoring or a trench shield

    OSHA's excavation standard (29 CFR 1926.652(a)(1)) requires each employee in an excavation to be protected from cave-ins by an adequate protective system, such as sloping, benching, shoring or a shield, unless the excavation is entirely in stable rock or is less than 5 feet deep and a competent person finds no sign of a potential cave-in. A 6-foot trench in soil meets neither exception. A spotter can't hold a wall up, protective gear doesn't stop a collapse, and ladders are a separate requirement: a way out within 25 feet of lateral travel in trenches 4 feet or deeper.

    Look for this next time: A trench 5 feet or deeper in soil needs a protective system against cave-ins, such as sloping, shoring or a shield.

  8. Question 8 · Administration General Regulations

    A drain line must offset 18 inches to clear a beam, using two 45-degree fittings. About how long is the diagonal run between the fittings, measured center to center?

    1. About 12 3/4 inches
    2. About 25 7/16 inches
    3. About 47 inches
    4. About 20 13/16 inches
    Show answer and explanation for question 8

    Correct answer: B · About 25 7/16 inches

    With 45-degree fittings, the offset and the run form a right triangle with two equal sides, and the diagonal, often called the travel, equals the offset times the square root of 2, about 1.414. Here 18 × 1.414 = 25.45 inches, or about 25 7/16. Multiplying by 0.707 instead gives about 12 3/4 inches, which works the formula backward. About 47 inches uses the factor for 22 1/2-degree fittings (about 2.613), and about 20 13/16 inches uses the factor for 60-degree fittings (about 1.155). Subtract the fitting allowances from the center-to-center length to get the cut length.

    Look for this next time: For a 45-degree offset, the center-to-center travel is about 1.414 times the offset.

  9. Question 9 · Plumbing Fixtures

    A homeowner picks out a new gravity flush tank toilet. Under the federal Department of Energy water standard, what is the most water it may use per flush?

    1. 1.0 gallon per flush
    2. 3.5 gallons per flush
    3. 1.6 gallons per flush
    4. 2.2 gallons per flush
    Show answer and explanation for question 9

    Correct answer: C · 1.6 gallons per flush

    The Department of Energy's water conservation standard (10 CFR 430.32(q)) caps gravity flush tank water closets at 1.6 gallons per flush. The 3.5-gallon figure belongs only to blowout bowl water closets, a separate class in the same table, and 1.0 gallon per flush is the limit for urinals. 2.2 is a lavatory or kitchen faucet's maximum flow in gallons per minute at 60 psi, a different measure entirely. Your exam's plumbing code has its own fixture table, so look up the figure there too.

    Look for this next time: Under the federal standard, a gravity flush tank water closet may use no more than 1.6 gallons per flush.

  10. Question 10 · Plumbing Fixtures

    A stadium restroom gets a new trough-type urinal 72 inches long. Under the federal Department of Energy water standard, what is the most water it may use per flush?

    1. 1.0 gallon per flush
    2. 6.0 gallons per flush
    3. 3.6 gallons per flush
    4. 4.5 gallons per flush
    Show answer and explanation for question 10

    Correct answer: D · 4.5 gallons per flush

    The federal standard (10 CFR 430.32(r)) caps urinals at 1.0 gallon per flush and sets a trough-type urinal's maximum as that rate multiplied by the trough's length in inches divided by 16 inches. Here 72 ÷ 16 = 4.5, so the limit is 4.5 gallons per flush. The single-urinal limit ignores the trough's length, 6.0 gallons divides by 12 as though the length were in feet, and 3.6 gallons divides by 20 inches, the figure the same section uses for lavatory sprayheads.

    Look for this next time: A trough urinal's federal maximum is 1.0 gallon per flush for every 16 inches of length.

  11. Question 11 · Plumbing Fixtures

    A plumber is piping the discharge from a new water heater's temperature and pressure relief valve. Which installation is correct?

    1. A line one size smaller than the valve outlet, since it rarely opens
    2. A line connected directly to the nearest drain so no water spills
    3. A line with a trap near its end to keep sewer gas out of the heater
    4. A full-size line that drains by gravity, with no trap and an unthreaded end
    Show answer and explanation for question 11

    Correct answer: D · A full-size line that drains by gravity, with no trap and an unthreaded end

    The federal manufactured home standard (24 CFR 3280.609(c)) requires relief valve drains with a cross-section equal to the valve outlet, piped full size, that drain fully by gravity, are not trapped and don't have threaded outlets, with the end visible for inspection. It also bars connecting the valve's outlet directly to the drainage system, so the direct drain connection fails, and the reduced line and the trapped line break the same rule. Plumbing codes add their own termination and material rules for this pipe, so check the section in your exam's code.

    Look for this next time: Pipe a relief valve full size, by gravity, without a trap or a threaded end, and never directly into a drain.

  12. Question 12 · Plumbing Fixtures

    A plumber installs a new pressure-balancing valve in a tub-shower. How should the valve's handle limit stop be set?

    1. To let the shower reach the water heater's full temperature
    2. To keep the mixed water at or above 140°F to control bacteria
    3. To a maximum of 120°F, so users can't select hotter mixed water
    4. It needs no setting, because balancing valves cap heat on their own
    Show answer and explanation for question 12

    Correct answer: C · To a maximum of 120°F, so users can't select hotter mixed water

    The federal manufactured home standard (24 CFR 3280.607) requires shower and tub-shower valves to be pressure-balancing, thermostatic or combination mixing valves meeting ASSE 1016, with handle position stops adjustable to a maximum setting of 120°F. A balancing valve holds the mix steady when supply pressure shifts, but the limit stop is what keeps a user from turning the mix hotter, so it has to be set. Letting the shower reach full heater temperature defeats the stop, and 140°F is above the limit. The same section limits hot water to bathtubs to 120°F with an ASSE 1070 device.

    Look for this next time: Set a shower valve's handle limit stop so the mixed water can't exceed 120°F.

  13. Question 13 · Water Supply and Distribution

    A new house's water service shows a static pressure of 95 psi at the meter. What should the plumber install to protect the building's piping and fixtures?

    1. A pressure-reducing valve to lower the pressure inside the building
    2. A larger water service pipe so the static pressure drops
    3. An expansion tank in place of a pressure-reducing valve
    4. Nothing, because higher pressure only improves the flow at fixtures
    Show answer and explanation for question 13

    Correct answer: A · A pressure-reducing valve to lower the pressure inside the building

    The federal manufactured home standard (24 CFR 3280.609(a)) designs homes for an inlet water pressure of 80 psi and requires the installation instructions to say that a pressure-reducing valve should be installed where the water pressure exceeds 80 psi. At 95 psi static, a pressure-reducing valve brings the building's pressure down. Static pressure is measured with no water flowing, so a larger service pipe doesn't lower it. An expansion tank absorbs the thermal expansion of heated water, a different job, and pressure above the design limit strains valves and fixtures. Check the pressure limit in your exam's code.

    Look for this next time: When static water pressure runs above the design limit, such as 80 psi, install a pressure-reducing valve.

  14. Question 14 · Water Supply and Distribution

    A lawn irrigation system is fed from a home's potable water piping through an atmospheric vacuum breaker. Which installation is correct?

    1. A shutoff valve downstream of the vacuum breaker so zones can be isolated
    2. The breaker at least 6 inches above the highest outlet, with no valve after it
    3. The vacuum breaker inside a valve box below grade, where it is protected
    4. The vacuum breaker as the only protection on a zone fed by a booster pump
    Show answer and explanation for question 14

    Correct answer: B · The breaker at least 6 inches above the highest outlet, with no valve after it

    EPA's Cross-Connection Control Manual says an atmospheric vacuum breaker protects against backsiphonage only, never backpressure, and must be installed vertically, with no shutoff downstream, at least 6 inches higher than the final outlet. A downstream valve would hold the device under constant pressure, so it couldn't vent to the atmosphere when it needs to. A breaker in a below-grade box sits lower than the sprinkler heads it protects, and a booster pump can create backpressure, which this device doesn't stop. Where valves must sit downstream, EPA describes the pressure vacuum breaker, which can stay under constant pressure.

    Look for this next time: An atmospheric vacuum breaker sits at least 6 inches above the highest outlet it serves, with no valve downstream, and handles backsiphonage only.

  15. Question 15 · Water Supply and Distribution

    A car wash injects a toxic cleaning chemical into water drawn from the building's potable supply, and its booster pump can push the wash piping above supply pressure. The water supplier rates the connection a high hazard. Which backflow preventer fits it?

    1. A reduced pressure principle backflow preventer assembly
    2. A double check valve assembly, since it stops backpressure
    3. A pressure vacuum breaker at the pump
    4. A hose bibb vacuum breaker
    Show answer and explanation for question 15

    Correct answer: A · A reduced pressure principle backflow preventer assembly

    EPA's Cross-Connection Control Manual says reduced pressure principle backflow preventers give maximum protection against both backsiphonage and backpressure, can be used under constant pressure and at high-hazard installations, and keep the zone between their two checks at least 2 psi below supply pressure, venting it through a relief valve. A double check valve assembly also handles backpressure, but EPA lists it for low- to medium-hazard installations. Pressure vacuum breakers and hose bibb vacuum breakers protect only against backsiphonage, so a booster pump that creates backpressure defeats them.

    Look for this next time: A high-hazard connection that can see backpressure calls for a reduced pressure principle backflow preventer.

  16. Question 16 · Sanitary Drainage

    A building drain runs 38 feet from its upper end to where it leaves the building, and the plans call for a slope of 1/4 inch per foot. How much lower is the outlet end?

    1. 4 3/4 inches
    2. 19 inches
    3. 2 3/8 inches
    4. 9 1/2 inches
    Show answer and explanation for question 16

    Correct answer: D · 9 1/2 inches

    Fall equals slope times length: 1/4 inch per foot × 38 feet = 9 1/2 inches. Four and three-quarter inches is the fall at 1/8 inch per foot, 2 3/8 inches the fall at 1/16 inch per foot, and 19 inches the fall at 1/2 inch per foot, so each of those uses the wrong slope. Required slopes depend on your code and the pipe size. The federal manufactured home standard, for example, sets 1/4 inch per foot for horizontal drainage piping and allows 1/8 inch only with a full-size cleanout at the upper end.

    Look for this next time: Fall equals slope times length: 1/4 inch per foot over 38 feet is 9 1/2 inches.

  17. Question 17 · Sanitary Drainage

    A rectangular sump pit measures 2 feet by 2 feet inside, and water stands 2 1/2 feet deep when the pump switches on. About how many gallons are in the pit at that point?

    1. 10 gallons
    2. About 38 gallons
    3. About 1.3 gallons
    4. About 75 gallons
    Show answer and explanation for question 17

    Correct answer: D · About 75 gallons

    The water forms a box of 2 × 2 × 2.5 = 10 cubic feet. NIST's conversion factors put a cubic foot at 0.02831685 cubic meter and a U.S. gallon at 0.003785412 cubic meter, so one cubic foot holds about 7.48 gallons, and 10 cubic feet hold about 75 gallons. Ten gallons skips the conversion, 1.3 gallons divides by 7.48 instead of multiplying, and 38 gallons multiplies by 3.785, the number of liters in a gallon.

    Look for this next time: Multiply cubic feet by about 7.48 to convert a volume to gallons.

  18. Question 18 · Sanitary Drainage

    A commercial kitchen's dishwasher drain is piped solidly into the building's sanitary drain, so a sewer backup could push wastewater into the machine. Which correction does EPA's cross-connection manual suggest?

    1. Have the dishwasher discharge to a receptor through an indirect waste
    2. Add a second trap to the dishwasher's drain line for extra protection
    3. Raise the dishwasher's supply pressure to hold waste back
    4. Run the dishwasher's drain into the vent stack instead of the drain
    Show answer and explanation for question 18

    Correct answer: A · Have the dishwasher discharge to a receptor through an indirect waste

    In EPA's backsiphonage Case 4, a dishwasher with a solid waste connection to the sewer is corrected by having its waste discharge through an indirect waste, along with protecting its water supply. An indirect waste ends above a receptor instead of joining the drain; the federal manufactured home standard defines an indirect waste receptor as one that keeps an air gap between the end of the waste pipe and the top of the drain. A backup then spills at the receptor instead of entering the machine. A second trap would double-trap the fixture, which that standard prohibits, supply pressure doesn't touch the drain connection, and a vent pipe is meant to carry air, not waste.

    Look for this next time: Draining a commercial dishwasher through an indirect waste keeps a sewer backup from reaching the machine.

  19. Question 19 · Plumbing Vent Requirements

    A lavatory's 1 1/2-inch trap arm runs 5 feet from the trap to the vent tee, sloped 1/4 inch per foot toward the vent. Does the vent opening stay above the trap's weir?

    1. No, because any fall of more than 1 inch drops the vent opening below the weir
    2. Yes, because its 1 1/4-inch total fall is less than the pipe's diameter
    3. No, because a trap arm must be installed level to protect the weir
    4. Yes, because a vent tee's height never affects a trap weir
    Show answer and explanation for question 19

    Correct answer: B · Yes, because its 1 1/4-inch total fall is less than the pipe's diameter

    The federal manufactured home standard (24 CFR 3280.606) grades a trap arm 1/4 inch per foot toward the vent, says its slope may never exceed its diameter, and bars the vent opening at the fixture tee from sitting below the weir of the trap. Five feet at 1/4 inch per foot is a 1 1/4-inch fall, less than the 1 1/2-inch diameter, so the vent opening stays above the weir. There's no fixed 1-inch limit, a level arm has no slope to carry waste, and the vent's height relative to the weir is exactly what keeps the arm from running full and siphoning the trap.

    Look for this next time: Keep a trap arm's total fall within one pipe diameter so the vent opening stays above the trap weir.

  20. Question 20 · Traps, Interceptors, and Separators

    A plumber replacing a lavatory trap has four traps to choose from. Which one meets the trap rules in the federal manufactured home standard?

    1. A P-trap with a 3-inch water seal
    2. A P-trap with a 1-inch water seal
    3. A P-trap with a 5-inch water seal
    4. A trap sealed by a concealed interior partition
    Show answer and explanation for question 20

    Correct answer: A · A P-trap with a 3-inch water seal

    The federal manufactured home standard (24 CFR 3280.606) requires each P-trap to hold a water seal of not less than 2 inches and not more than 4 inches, set true to its seal, so the 3-inch trap fits. A 1-inch seal is below the minimum and a 5-inch seal is above the maximum. The same section bans traps that depend on concealed interior partitions for their seal, along with full S traps, bell traps, drum traps, crown-vented traps and running traps, and it bars double-trapping a fixture.

    Look for this next time: A P-trap's water seal must be at least 2 inches and no more than 4 inches deep.

Use the sample well

The rationale matters more than the score.

A short set can show you what deserves another look. A strong run shows you can do what a journeyman plumbing exam asks: spot the detail that decides a code question, then apply the rule or the calculation. Twenty questions are a small sample, so the result does not predict a pass on your state's exam.

01

Answer before reviewing

Choose the one best answer for the situation as written. Then read why each other option falls short.

02

Read every rationale

Confirm why the best option fits, even when you were right.

03

Follow the pattern

Use recurring misses—not one score—to choose your next focus.